Specifications Wingsuit

Wingsuit CYPRES 2

Wing Suit Status:
Activation altitude Wing Suit Status: approx. 750 – 130 feet
Activation speed Wing Suit Status: approx. > 45 mph (20 m/s)
Canopy Status:
Activation altitude Canopy Status: according to set MODE
Activation speed Canopy Status: according to set MODE
Status Change:
between approx. 6500 feet (2000 meters) and
approx. 1500 feet (450 meters) above ground
when descending less than approx. 19 mph (8,5 m/s), but more
than approx. 5.6 mph (2.5 m/s)
for 6-20 seconds depending on where this
status change time is programmed
Default status change time 10 seconds
Volume: approx. 139 cm³
Weight: approx. 198 grams
Length, width, height of the processing unit: approx. 85 x 43 x 32 mm
Length, width, height of the control unit: approx. 65 x 18 x 6.5 mm
Cable length of control unit: approx. 650 mm
Length, diameter of the release unit: approx. 43 x 8 mm
Cable length of the release unit (including release unit): approx. 500 mm
Storage temperature: +71° to -25° Celsius
Storage pressure: 200 to 1094 hPa ( 5.906 to 32.306 In.Hg)
Working temperature: +63° to -20° Celsius*
Maximum allowable humidity: up to 99.9 % rel. humidity
Waterproof: up to 24 hours down to a depth of 8 feet (2.5 meters)
Dropzone offset adjustment limits: ±1050 feet or ±350 m
Operating range below / above sea level: -2140 feet to +26,000 feet (-650 m to +8000 m)
Functioning period: 14 hours from switch-on
Power supply: service life warranty**
Maintenance:

For units with DOM 01/17 and later the maintenance can be performed on a voluntary basis 5 and 10 years after the original DOM. Service Life is 15.5 years.***

Warranty Period: see Airtec warranty policy
Service life: DOM later 01.01.2017: 15.5 years from date of manufacture
*These temperature limits do not mean the outside (ambient) temperatures but rather temperatures inside the processing unit. Therefore, these limits won‘t have any meaning until the processing unit itself has reached the temperatures in question. In actual fact, these limits will rarely be reached due to the location of the CYPRES in the reserve container, and the insulating properties of the processing unit pouch and parachute canopies.

** If maintenances have been performed within the scheduled time frames.

*** According to the present knowledge base.